1. NAME

sane-umax1220u - SANE backend for the UMAX Astra 1220U and similar scanners

2. DESCRIPTION

The

sane-umax1220 library implements a SANE (Scanner Access Now Easy) backend for the the UMAX Astra 1220U and similar scanners. For more information on this backend, please visit http://umax1220u-sane.sourceforge.net/ .

3. UMAX ASTRA 1600U/2000U/2100U SUPPORT

This backend is also able to drive the UMAX Astra 1600U/2000U/2100U. The 2100U is confirmed to work. For the other scanners no reports have been received yet. Please contact us and tell us if your scanner works ().

4. CONFIGURATION

Usually, no manual configuration is necessary. The configuration file for this backend resides in /etc/sane.d/umax1220u.conf . Its contents is a list of device names that correspond to UMAX Astra scanners. Empty lines and lines starting with a hash mark (#) are ignored. A sample configuration file is shown below:

 
Sélectionnez
#usb vendor product
 usb 0x1606 0x0010
 # Device list for non-linux systems
 /dev/scanner
 /dev/usb/scanner0

See sane-usb(5) for information on how to set the access permissions on the usb device files.

5. FILES

  • The backend configuration file:
        .I /etc/sane.d/umax1220u.conf
  • The static library implementing this backend:
        .I /usr/lib/sane/libsane-umax1220u.a
  • The shared library implementing this backend:
        .I /usr/lib/sane/libsane-umax1220u.so (present on systems that support dynamic loading)

6. ENVIRONMENT

SANE_DEBUG_UMAX1220U

    If the library was compiled with debug support enabled, this environment variable controls the debug level for this backend. E.g., a value of 128 requests all debug output to be printed. Smaller levels reduce verbosity: SANE_DEBUG_UMAX1220U values

 
Sélectionnez
Number  Remark
 1       print failures
 2       print information
 3       print high-level function calls
 4       print high-level function checkpoints
 9       print mid-level function calls
 10      print mid-level function checkpoints
 80      print protocol-level function entry
 90      print protocol-level function exit
  • Example:
        export SANE_DEBUG_UMAX1220U=10

7. KNOWN BUGS

600 dpi scanning may fail for large image sizes. If you keep getting I/O errors, try cycling the power on your scanner to reset it. There is no way to cancel a scan, since the driver ignores sane_cancel(). If you try scanning an image which is too small, you will get I/O errors. Be sure to adjust the scan area before doing a scan, since by default, the scan area is zero.

8. SEE ALSO

sane(7), sane-usb(5)

9. AUTHOR

Marcio Luis Teixeira <>

10. EMAIL-CONTACT

11. REPORTING BUGS

This backend isn't actively maintained. Nevertheless, bug reports and comments should be sent to the sane-devel mailing list. When reporting bugs, please run the backend with SANE_DEBUG_UMAX1220U set to 10 and attach a copy of the log messages.